API endpoint for user synchronization in 2N Access Commander version 3.4.1 did not have a sufficient input validation allowing for OS command injection. This vulnerability can only be exploited after authenticating with administrator privileges.
CVE Details
CVSS v3.1 Score7.2
SeverityHIGH
CVSS VectorCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Attack VectorNETWORK
ComplexityLOW
Privileges RequiredHIGH
User InteractionNONE
Published3/4/2026
Last Modified3/5/2026
Sourcenvd
Honeypot Sightings0
Affected Products
2n:access_commander
Weaknesses (CWE)
CWE-78
References
https://www.2n.com/en-GB/download/cve_2025_59783_acom_3_5_v1pdf(be69f613-e5f6-419b-800c-30351aa8933c)