← Back to CVEs
CVE-2024-37570
HIGH8.8
Description
On Mitel 6869i 4.5.0.41 devices, the Manual Firmware Update (upgrade.html) page does not perform sanitization on the username and path parameters (sent by an authenticated user) before appending flags to the busybox ftpget command. This leads to $() command execution.
CVE Details
CVSS v3.1 Score8.8
SeverityHIGH
CVSS VectorCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack VectorNETWORK
ComplexityLOW
Privileges RequiredLOW
User InteractionNONE
Published6/9/2024
Last Modified11/21/2024
Sourcenvd
Honeypot Sightings0
Affected Products
mitel:6869i_sipmitel:6869i_sip_firmware
Weaknesses (CWE)
CWE-77CWE-77
References
https://github.com/kwburns/CVE/tree/main/Mitel/5.0.0.1018#authenticated-remote-command-execution-firmware(cve@mitre.org)
https://github.com/kwburns/CVE/blob/main/Mitel/5.0.0.1018/code/exploit-firmware.py(af854a3a-2127-422b-91ae-364da2661108)
https://github.com/kwburns/CVE/tree/main/Mitel/5.0.0.1018#authenticated-remote-command-execution-firmware(af854a3a-2127-422b-91ae-364da2661108)
IOC Correlations
No correlations recorded
This product uses data from the NVD API but is not endorsed or certified by the NVD.