Description
Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected. Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives. This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.
CVE Details
CVSS v3.1 Score5.9
SeverityMEDIUM
CVSS VectorCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:N/A:H
Attack VectorLOCAL
ComplexityLOW
Privileges RequiredLOW
User InteractionREQUIRED
Published6/13/2023
Last Modified11/21/2024
Sourcenvd
Honeypot Sightings0
Affected Products
rockwellautomation:factorytalk_policy_managerrockwellautomation:factorytalk_system_services
Weaknesses (CWE)
CWE-287CWE-287
References
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683(PSIRT@rockwellautomation.com)
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683(af854a3a-2127-422b-91ae-364da2661108)
IOC Correlations
No correlations recorded
This product uses data from the NVD API but is not endorsed or certified by the NVD.