TROYANOSYVIRUS
Back to CVEs

CVE-2020-9477

CRITICAL
9.8

Description

An issue was discovered on HUMAX HGA12R-02 BRGCAA 1.1.53 devices. A vulnerability in the authentication functionality in the web-based interface could allow an unauthenticated remote attacker to capture packets at the time of authentication and gain access to the cleartext password. An attacker could use this access to create a new user account or control the device.

CVE Details

CVSS v3.1 Score9.8
SeverityCRITICAL
CVSS VectorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack VectorNETWORK
ComplexityLOW
Privileges RequiredNONE
User InteractionNONE
Published3/4/2020
Last Modified11/21/2024
Sourcenvd
Honeypot Sightings0

Affected Products

humaxdigital:hga12r-02humaxdigital:hga12r-02_firmware

Weaknesses (CWE)

CWE-319

IOC Correlations

No correlations recorded