Description
Incorrect Access Control in Beckhoff Automation GmbH & Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the "CE Remote Display Tool" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect.
CVE Details
CVSS v3.1 Score9.8
SeverityCRITICAL
CVSS VectorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack VectorNETWORK
ComplexityLOW
Privileges RequiredNONE
User InteractionNONE
Published7/23/2021
Last Modified11/21/2024
Sourcenvd
Honeypot Sightings0
Affected Products
beckhoff:cx9020
References
https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf(cve@mitre.org)
https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf(af854a3a-2127-422b-91ae-364da2661108)