CVE-2020-10276

CRITICAL
9.8

Description

The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.

CVE Details

CVSS v3.1 Score9.8
SeverityCRITICAL
CVSS VectorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack VectorNETWORK
ComplexityLOW
Privileges RequiredNONE
User InteractionNONE
Published6/24/2020
Last Modified11/21/2024
Sourcenvd
Honeypot Sightings0

Affected Products

easyrobotics:er-flexeasyrobotics:er-flex_firmwareeasyrobotics:er-liteeasyrobotics:er-lite_firmwareeasyrobotics:er-oneeasyrobotics:er-one_firmwareeasyrobotics:er200easyrobotics:er200_firmwaremobile-industrial-robots:mir100mobile-industrial-robots:mir1000mobile-industrial-robots:mir1000_firmwaremobile-industrial-robots:mir100_firmwaremobile-industrial-robots:mir200mobile-industrial-robots:mir200_firmwaremobile-industrial-robots:mir250mobile-industrial-robots:mir250_firmwaremobile-industrial-robots:mir500mobile-industrial-robots:mir500_firmwareuvd-robots:uvduvd-robots:uvd_firmware

Weaknesses (CWE)

CWE-798CWE-798

References

IOC Correlations

No correlations recorded

This product uses data from the NVD API but is not endorsed or certified by the NVD.