← Back to CVEs
CVE-2019-5138
CRITICAL9.9
Description
An exploitable command injection vulnerability exists in encrypted diagnostic script functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted diagnostic script file can cause arbitrary busybox commands to be executed, resulting in remote control over the device. An attacker can send diagnostic while authenticated as a low privilege user to trigger this vulnerability.
CVE Details
CVSS v3.1 Score9.9
SeverityCRITICAL
CVSS VectorCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Attack VectorNETWORK
ComplexityLOW
Privileges RequiredLOW
User InteractionNONE
Published2/25/2020
Last Modified11/21/2024
Sourcenvd
Honeypot Sightings0
Affected Products
moxa:awk-3131amoxa:awk-3131a_firmware
Weaknesses (CWE)
CWE-78CWE-78
References
https://talosintelligence.com/vulnerability_reports/TALOS-2019-0927(talos-cna@cisco.com)
https://talosintelligence.com/vulnerability_reports/TALOS-2019-0927(af854a3a-2127-422b-91ae-364da2661108)
IOC Correlations
No correlations recorded
This product uses data from the NVD API but is not endorsed or certified by the NVD.