Description

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR) (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.

CVE Details

CVSS v3.1 Score8.6
SeverityHIGH
CVSS VectorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
Attack VectorNETWORK
ComplexityLOW
Privileges RequiredNONE
User InteractionNONE
Published8/13/2019
Last Modified11/21/2024
Sourcenvd
Honeypot Sightings0

Affected Products

siemens:scalance_x-200siemens:scalance_x-200_firmwaresiemens:scalance_x-200irtsiemens:scalance_x-200irt_firmwaresiemens:scalance_x-200rnasiemens:scalance_x-200rna_firmware

Weaknesses (CWE)

CWE-400CWE-400

IOC Correlations

No correlations recorded