A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
CVE Details
CVSS v3.1 ScoreN/A
Published6/30/2017
Last Modified4/20/2025
Sourcenvd
Honeypot Sightings0
Affected Products
schneider-electric:bmxnoc0401schneider-electric:bmxnoc0401_firmwareschneider-electric:bmxnoe0100schneider-electric:bmxnoe0100_firmwareschneider-electric:bmxnoe0110schneider-electric:bmxnoe0110_firmwareschneider-electric:bmxnoe0110hschneider-electric:bmxnoe0110h_firmwareschneider-electric:bmxnor0200hschneider-electric:bmxnor0200h_firmwareschneider-electric:modicon_m340_bmxp341000schneider-electric:modicon_m340_bmxp341000_firmwareschneider-electric:modicon_m340_bmxp342000schneider-electric:modicon_m340_bmxp342000_firmwareschneider-electric:modicon_m340_bmxp3420102schneider-electric:modicon_m340_bmxp3420102_firmwareschneider-electric:modicon_m340_bmxp3420102clschneider-electric:modicon_m340_bmxp3420102cl_firmwareschneider-electric:modicon_m340_bmxp342020schneider-electric:modicon_m340_bmxp342020_firmwareschneider-electric:modicon_m340_bmxp342020hschneider-electric:modicon_m340_bmxp342020h_firmwareschneider-electric:modicon_m340_bmxp342030schneider-electric:modicon_m340_bmxp3420302schneider-electric:modicon_m340_bmxp3420302_firmwareschneider-electric:modicon_m340_bmxp3420302hschneider-electric:modicon_m340_bmxp3420302h_firmwareschneider-electric:modicon_m340_bmxp342030_firmwareschneider-electric:modicon_m340_bmxp342030hschneider-electric:modicon_m340_bmxp342030h_firmware
Weaknesses (CWE)
CWE-400CWE-400
References
http://www.securityfocus.com/bid/96414(ics-cert@hq.dhs.gov)
https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03(ics-cert@hq.dhs.gov)
https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/(ics-cert@hq.dhs.gov)
http://www.securityfocus.com/bid/96414(af854a3a-2127-422b-91ae-364da2661108)
https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03(af854a3a-2127-422b-91ae-364da2661108)