TROYANOSYVIRUS
Back to CVEs

CVE-2013-2805

N/A

Description

Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599

CVE Details

CVSS v3.1 ScoreN/A
Published3/26/2019
Last Modified11/21/2024
Sourcenvd
Honeypot Sightings0

Affected Products

rockwellautomation:rslinx_enterprise

Weaknesses (CWE)

CWE-125CWE-125

IOC Correlations

No correlations recorded

This product uses data from the NVD API but is not endorsed or certified by the NVD.