TROYANOSYVIRUS
Voltar para CVEs

CVE-2026-25857

HIGH
8.8

Descricao

Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.

Detalhes CVE

Pontuacao CVSS v3.18.8
SeveridadeHIGH
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosLOW
Interacao do usuarioNONE
Publicado2/7/2026
Ultima modificacao3/5/2026
Fontenvd
Avistamentos honeypot0

Produtos afetados

tenda:g300-ftenda:g300-f_firmware

Fraquezas (CWE)

CWE-78

Correlacoes IOC

Sem correlacoes registradas

This product uses data from the NVD API but is not endorsed or certified by the NVD.