TROYANOSYVIRUS
Voltar para CVEs

CVE-2025-70161

CRITICAL
9.8

Descricao

EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution.

Detalhes CVE

Pontuacao CVSS v3.19.8
SeveridadeCRITICAL
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosNONE
Interacao do usuarioNONE
Publicado1/9/2026
Ultima modificacao1/22/2026
Fontenvd
Avistamentos honeypot0

Produtos afetados

edimax:br-6208acedimax:br-6208ac_firmware

Fraquezas (CWE)

CWE-77

Correlacoes IOC

Sem correlacoes registradas