← Voltar para CVEs
CVE-2025-30042
HIGH7.8
Descricao
The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.
Detalhes CVE
Pontuacao CVSS v3.17.8
SeveridadeHIGH
Vetor CVSSCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueLOCAL
ComplexidadeLOW
Privilegios necessariosLOW
Interacao do usuarioNONE
Publicado3/2/2026
Ultima modificacao3/9/2026
Fontenvd
Avistamentos honeypot0
Produtos afetados
cgm:clininet
Fraquezas (CWE)
CWE-603