TROYANOSYVIRUS
Voltar para CVEs

CVE-2025-11786

CRITICAL
9.8

Descricao

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'SetUserPassword()' function, the 'newPassword' parameter is directly embedded in a shell command string using 'sprintf()' without any sanitisation or validation, and then executed using 'system()'. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application.

Detalhes CVE

Pontuacao CVSS v3.19.8
SeveridadeCRITICAL
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosNONE
Interacao do usuarioNONE
Publicado12/2/2025
Ultima modificacao12/3/2025
Fontenvd
Avistamentos honeypot0

Produtos afetados

circutor:sge-plc1000circutor:sge-plc1000_firmwarecircutor:sge-plc50circutor:sge-plc50_firmware

Fraquezas (CWE)

CWE-121

Correlacoes IOC

Sem correlacoes registradas

This product uses data from the NVD API but is not endorsed or certified by the NVD.