TROYANOSYVIRUS
Voltar para CVEs

CVE-2025-11782

CRITICAL
9.8

Descricao

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'ShowDownload()' function uses “sprintf()” to format a string that includes the user-controlled input of 'GetParameter(meter)' in the fixed-size buffer 'acStack_4c' (64 bytes) without checking the length. An attacker can provide an excessively long value for the 'meter' parameter that exceeds the 64-byte buffer size.

Detalhes CVE

Pontuacao CVSS v3.19.8
SeveridadeCRITICAL
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosNONE
Interacao do usuarioNONE
Publicado12/2/2025
Ultima modificacao12/3/2025
Fontenvd
Avistamentos honeypot0

Produtos afetados

circutor:sge-plc1000circutor:sge-plc1000_firmwarecircutor:sge-plc50circutor:sge-plc50_firmware

Fraquezas (CWE)

CWE-121

Correlacoes IOC

Sem correlacoes registradas

This product uses data from the NVD API but is not endorsed or certified by the NVD.