← Voltar para CVEs
CVE-2024-38878
HIGH7.2
Descricao
A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). Affected devices allow authenticated users to export diagnostics data. The corresponding API endpoint is susceptible to path traversal and could allow an authenticated attacker to download arbitrary files from the file system.
Detalhes CVE
Pontuacao CVSS v3.17.2
SeveridadeHIGH
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosHIGH
Interacao do usuarioNONE
Publicado8/2/2024
Ultima modificacao11/3/2025
Fontenvd
Avistamentos honeypot0
Produtos afetados
siemens:omnivise_t3000_application_server
Fraquezas (CWE)
CWE-22
Referencias
https://cert-portal.siemens.com/productcert/html/ssa-857368.html(productcert@siemens.com)
http://seclists.org/fulldisclosure/2024/Nov/5(af854a3a-2127-422b-91ae-364da2661108)
Correlacoes IOC
Sem correlacoes registradas
This product uses data from the NVD API but is not endorsed or certified by the NVD.