← Voltar para CVEs
CVE-2023-24512
HIGH8.8
Descricao
On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft a request allowing it to update arbitrary configurations in the switch. This situation occurs only when the Streaming Telemetry Agent (referred to as the TerminAttr agent) is enabled and gNMI access is configured on the agent. Note: This gNMI over the Streaming Telemetry Agent scenario is mostly commonly used when streaming to a 3rd party system and is not used by default when streaming to CloudVision
Detalhes CVE
Pontuacao CVSS v3.18.8
SeveridadeHIGH
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosLOW
Interacao do usuarioNONE
Publicado4/25/2023
Ultima modificacao11/21/2024
Fontenvd
Avistamentos honeypot0
Produtos afetados
arista:32qdarista:48ehsarista:48lbasarista:48lbsarista:48s6qdarista:7010t-48arista:7020sr-24c2arista:7020sr-32c2arista:7020tr-48arista:7020tra-48arista:7050cx3-32sarista:7050cx3m-32sarista:7050qx-32sarista:7050qx2-32sarista:7050sx-128arista:7050sx-64arista:7050sx-72qarista:7050sx2-128arista:7050sx2-72qarista:7050sx3-48c8arista:7050sx3-48ycarista:7050sx3-48yc12arista:7050sx3-48yc8arista:7050sx3-96yc8arista:7050tx-48arista:7050tx-64arista:7050tx-72qarista:7050tx2-128arista:7050tx3-48c8arista:7060cx-32sarista:7060cx2-32sarista:7060dx4-32arista:7060px4-32arista:7060sx2-48yc6arista:7130-16g3sarista:7130-48g3sarista:7130-96sarista:7150s-24arista:7150s-52arista:7150s-64arista:7150sc-24arista:7150sc-64arista:7160-32cqarista:7160-48tc6arista:7160-48yc6arista:7170-32carista:7170-32cdarista:7170-64carista:7170b-64carista:720df-48yarista:720dp-24sarista:720dp-48sarista:720dt-24sarista:720dt-48sarista:720xp-24y6arista:720xp-24zy4arista:720xp-48y6arista:720xp-48zc2arista:720xp-96zc2arista:7250qx-64arista:7260cxarista:7260cx3arista:7260qxarista:7260sx2arista:7280cr2k-60arista:7280cr3-32d4arista:7280cr3-32p4arista:7280cr3-96arista:7280cr3k-32d4arista:7280cr3k-32p4arista:7280cr3k-96arista:7280dr3-24arista:7280dr3k-24arista:7280earista:7280pr3-24arista:7280pr3k-24arista:7280sr3-48yc8arista:7280sr3k-48yc8arista:7300x-32qarista:7300x-64sarista:7300x-64tarista:7300x3-32carista:7300x3-48yc4arista:7320x-32carista:7358x4arista:7368x4arista:7388x5arista:7500r3-24darista:7500r3-24parista:7500r3-36cqarista:7500r3k-36cqarista:7804r3arista:7808r3arista:7812r3arista:7816r3arista:96lbsarista:ceos-labarista:cloudeosarista:dcs-7010tx-48arista:dcs-7500-12cq-lcarista:dcs-7500e-12cm-lcarista:dcs-7500e-36q-lcarista:dcs-7500e-48s-lcarista:dcs-7500e-6c2-lcarista:dcs-7500e-72s-lcarista:dcs-7500r-36cq-lcarista:dcs-7500r-36q-lcarista:dcs-7500r-48s2cq-lcarista:eosarista:veos-lab
Fraquezas (CWE)
CWE-284CWE-863
Referencias
https://www.arista.com/en/support/advisories-notices/security-advisory/17250-security-advisory-0086(psirt@arista.com)
https://www.arista.com/en/support/advisories-notices/security-advisory/17250-security-advisory-0086(af854a3a-2127-422b-91ae-364da2661108)
Correlacoes IOC
Sem correlacoes registradas
This product uses data from the NVD API but is not endorsed or certified by the NVD.