CVE-2022-29875

CRITICAL
9.8

Descricao

A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC20D), NAEOTOM Alpha (All VA40 versions < VA40 SP2), SOMATOM X.cite (All versions < VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions < VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions < VB22A-UD03), Symbia Evo (All VB22 versions < VB22A-UD03), Symbia Intevo (All VB22 versions < VB22A-UD03), Symbia T (All VB22 versions < VB22A-UD03), Symbia.net (All VB22 versions < VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions < VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions < VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable.

Detalhes CVE

Pontuacao CVSS v3.19.8
SeveridadeCRITICAL
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosNONE
Interacao do usuarioNONE
Publicado6/1/2022
Ultima modificacao11/21/2024
Fontenvd
Avistamentos honeypot0

Produtos afetados

siemens:biograph_horizon_pet\/ct_systemssiemens:biograph_horizon_pet\/ct_systems_firmwaresiemens:magnetom_numaris_xsiemens:magnetom_numaris_x_firmwaresiemens:mammomat_revelationsiemens:mammomat_revelation_firmwaresiemens:naeotom_alphasiemens:naeotom_alpha_firmwaresiemens:somatom_go.allsiemens:somatom_go.all_firmwaresiemens:somatom_go.nowsiemens:somatom_go.now_firmwaresiemens:somatom_go.open_prosiemens:somatom_go.open_pro_firmwaresiemens:somatom_go.simsiemens:somatom_go.sim_firmwaresiemens:somatom_go.upsiemens:somatom_go.up_firmwaresiemens:somatom_x.citesiemens:somatom_x.cite_firmwaresiemens:somatom_x.creedsiemens:somatom_x.creed_firmwaresiemens:symbia.netsiemens:symbia_esiemens:symbia_e_firmwaresiemens:symbia_evosiemens:symbia_evo_firmwaresiemens:symbia_intevosiemens:symbia_intevo_firmwaresiemens:symbia_ssiemens:symbia_s_firmwaresiemens:symbia_tsiemens:symbia_t_firmwaresiemens:syngo.via

Fraquezas (CWE)

CWE-502CWE-502

Correlacoes IOC

Sem correlacoes registradas