TROYANOSYVIRUS
Voltar para CVEs

CVE-2020-15787

CRITICAL
9.8

Descricao

A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

Detalhes CVE

Pontuacao CVSS v3.19.8
SeveridadeCRITICAL
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosNONE
Interacao do usuarioNONE
Publicado9/9/2020
Ultima modificacao11/21/2024
Fontenvd
Avistamentos honeypot0

Produtos afetados

siemens:simatic_hmi_united_comfort_panelssiemens:simatic_hmi_united_comfort_panels_firmware

Fraquezas (CWE)

CWE-305CWE-287

Correlacoes IOC

Sem correlacoes registradas