← Voltar para CVEs
CVE-2019-7666
HIGH8.8
Descricao
Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password.
Detalhes CVE
Pontuacao CVSS v3.18.8
SeveridadeHIGH
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosLOW
Interacao do usuarioNONE
Publicado7/1/2019
Ultima modificacao11/21/2024
Fontenvd
Avistamentos honeypot0
Produtos afetados
primasystems:flexair
Fraquezas (CWE)
CWE-287
Referencias
http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html(cve@mitre.org)
https://applied-risk.com/labs/advisories(cve@mitre.org)
https://www.applied-risk.com/resources/ar-2019-007(cve@mitre.org)
https://www.us-cert.gov/ics/advisories/icsa-19-211-02(cve@mitre.org)
http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html(af854a3a-2127-422b-91ae-364da2661108)
https://applied-risk.com/labs/advisories(af854a3a-2127-422b-91ae-364da2661108)
https://www.applied-risk.com/resources/ar-2019-007(af854a3a-2127-422b-91ae-364da2661108)
https://www.us-cert.gov/ics/advisories/icsa-19-211-02(af854a3a-2127-422b-91ae-364da2661108)
Correlacoes IOC
Sem correlacoes registradas
This product uses data from the NVD API but is not endorsed or certified by the NVD.