TROYANOSYVIRUS
Voltar para CVEs

CVE-2019-10942

HIGH
8.6

Descricao

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR) (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.

Detalhes CVE

Pontuacao CVSS v3.18.6
SeveridadeHIGH
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosNONE
Interacao do usuarioNONE
Publicado8/13/2019
Ultima modificacao11/21/2024
Fontenvd
Avistamentos honeypot0

Produtos afetados

siemens:scalance_x-200siemens:scalance_x-200_firmwaresiemens:scalance_x-200irtsiemens:scalance_x-200irt_firmwaresiemens:scalance_x-200rnasiemens:scalance_x-200rna_firmware

Fraquezas (CWE)

CWE-400CWE-400

Correlacoes IOC

Sem correlacoes registradas

This product uses data from the NVD API but is not endorsed or certified by the NVD.