TROYANOSYVIRUS
Voltar para CVEs

CVE-2018-4842

N/A

Descricao

A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.

Detalhes CVE

Pontuacao CVSS v3.1N/A
Publicado6/14/2018
Ultima modificacao11/21/2024
Fontenvd
Avistamentos honeypot0

Produtos afetados

siemens:scalance_x200siemens:scalance_x200_firmwaresiemens:scalance_x200_irtsiemens:scalance_x200irt_firmwaresiemens:scalance_x300siemens:scalance_x300_firmware

Fraquezas (CWE)

CWE-79CWE-79

Referencias

Correlacoes IOC

Sem correlacoes registradas