TROYANOSYVIRUS
Voltar para CVEs

CVE-2017-9857

N/A

Descricao

An issue was discovered in SMA Solar Technology products. The SMAdata2+ communication protocol does not properly use authentication with encryption: it is vulnerable to man in the middle, packet injection, and replay attacks. Any setting change, authentication packet, scouting packet, etc. can be replayed, injected, or used for a man in the middle session. All functionalities available in Sunny Explorer can effectively be done from anywhere within the network as long as an attacker gets the packet setup correctly. This includes the authentication process for all (including hidden) access levels and the changing of settings in accordance with the gained access rights. Furthermore, because the SMAdata2+ communication channel is unencrypted, an attacker capable of understanding the protocol can eavesdrop on communications. NOTE: the vendor's position is that authentication with encryption is not required on an isolated subnetwork. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Detalhes CVE

Pontuacao CVSS v3.1N/A
Publicado8/5/2017
Ultima modificacao4/20/2025
Fontenvd
Avistamentos honeypot0

Produtos afetados

sma:sunny_boy_1.5sma:sunny_boy_1.5_firmwaresma:sunny_boy_2.5sma:sunny_boy_2.5_firmwaresma:sunny_boy_3.0sma:sunny_boy_3.0_firmwaresma:sunny_boy_3.6sma:sunny_boy_3.6_firmwaresma:sunny_boy_3000tlsma:sunny_boy_3000tl_firmwaresma:sunny_boy_3600sma:sunny_boy_3600_firmwaresma:sunny_boy_3600tlsma:sunny_boy_3600tl_firmwaresma:sunny_boy_4.0sma:sunny_boy_4.0_firmwaresma:sunny_boy_4000tlsma:sunny_boy_4000tl_firmwaresma:sunny_boy_5.0sma:sunny_boy_5.0_firmwaresma:sunny_boy_5000sma:sunny_boy_5000_firmwaresma:sunny_boy_5000tlsma:sunny_boy_5000tl_firmwaresma:sunny_boy_storage_2.5sma:sunny_boy_storage_2.5_firmwaresma:sunny_central_1000cp_xtsma:sunny_central_1000cp_xt_firmwaresma:sunny_central_2200sma:sunny_central_2200_firmwaresma:sunny_central_500cp_xtsma:sunny_central_500cp_xt_firmwaresma:sunny_central_630cp_xtsma:sunny_central_630cp_xt_firmwaresma:sunny_central_720cp_xtsma:sunny_central_720cp_xt_firmwaresma:sunny_central_760cp_xtsma:sunny_central_760cp_xt_firmwaresma:sunny_central_800cp_xtsma:sunny_central_800cp_xt_firmwaresma:sunny_central_850cp_xtsma:sunny_central_850cp_xt_firmwaresma:sunny_central_900cp_xtsma:sunny_central_900cp_xt_firmwaresma:sunny_central_storage_1000sma:sunny_central_storage_1000_firmwaresma:sunny_central_storage_2200sma:sunny_central_storage_2200_firmwaresma:sunny_central_storage_2500-evsma:sunny_central_storage_2500-ev_firmwaresma:sunny_central_storage_500sma:sunny_central_storage_500_firmwaresma:sunny_central_storage_630sma:sunny_central_storage_630_firmwaresma:sunny_central_storage_720sma:sunny_central_storage_720_firmwaresma:sunny_central_storage_760sma:sunny_central_storage_760_firmwaresma:sunny_central_storage_800sma:sunny_central_storage_800_firmwaresma:sunny_central_storage_850sma:sunny_central_storage_850_firmwaresma:sunny_central_storage_900sma:sunny_central_storage_900_firmwaresma:sunny_tripower_12000tlsma:sunny_tripower_12000tl_firmwaresma:sunny_tripower_15000tlsma:sunny_tripower_15000tl_firmwaresma:sunny_tripower_20000tlsma:sunny_tripower_20000tl_firmwaresma:sunny_tripower_25000tlsma:sunny_tripower_25000tl_firmwaresma:sunny_tripower_5000tlsma:sunny_tripower_5000tl_firmwaresma:sunny_tripower_60sma:sunny_tripower_60_firmwaresma:sunny_tripower_core1sma:sunny_tripower_core1_firmware

Fraquezas (CWE)

CWE-287

Correlacoes IOC

Sem correlacoes registradas

This product uses data from the NVD API but is not endorsed or certified by the NVD.