← Voltar para CVEs
CVE-2017-5159
CRITICAL9.8
Descricao
An issue was discovered on Phoenix Contact mGuard devices that have been updated to Version 8.4.0. When updating an mGuard device to Version 8.4.0 via the update-upload facility, the update will succeed, but it will reset the password of the admin user to its default value.
Detalhes CVE
Pontuacao CVSS v3.19.8
SeveridadeCRITICAL
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosNONE
Interacao do usuarioNONE
Publicado2/13/2017
Ultima modificacao4/20/2025
Fontenvd
Avistamentos honeypot0
Produtos afetados
phoenixcontact:mguard_firmware
Fraquezas (CWE)
CWE-99
Referencias
http://www.securityfocus.com/bid/95648(ics-cert@hq.dhs.gov)
https://ics-cert.us-cert.gov/advisories/ICSA-17-017-01(ics-cert@hq.dhs.gov)
http://www.securityfocus.com/bid/95648(af854a3a-2127-422b-91ae-364da2661108)
https://ics-cert.us-cert.gov/advisories/ICSA-17-017-01(af854a3a-2127-422b-91ae-364da2661108)
Correlacoes IOC
Sem correlacoes registradas