← Voltar para CVEs
CVE-2017-16341
CRITICAL9.9
Descricao
An attacker could send an authenticated HTTP request to trigger this vulnerability in Insteon Hub running firmware version 1012. At 0x9d01c224 the value for the s_vol_play key is copied using strcpy to the buffer at 0xa0000418. This buffer is maximum 8 bytes large (this is the maximum size it could be, it is possible other global variables are stored between this variable and the next one that we could identify), sending anything longer will cause a buffer overflow.
Detalhes CVE
Pontuacao CVSS v3.19.9
SeveridadeCRITICAL
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosLOW
Interacao do usuarioNONE
Publicado8/2/2018
Ultima modificacao11/21/2024
Fontenvd
Avistamentos honeypot0
Produtos afetados
insteon:hubinsteon:hub_firmware
Fraquezas (CWE)
CWE-120
Referencias
https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0484(talos-cna@cisco.com)
https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0484(af854a3a-2127-422b-91ae-364da2661108)
Correlacoes IOC
Sem correlacoes registradas
This product uses data from the NVD API but is not endorsed or certified by the NVD.