Descricao

A security researcher found an XML External Entity (XXE) vulnerability on the Conserus Image Repository archive solution version 2.1.1.105 by McKesson Medical Imaging Company, which is now a Change Healthcare company. An unauthenticated user supplying a modified HTTP SOAP request to the vulnerable service allows for arbitrary file read access to the local file system as well as the transmittal of the application service's account hashed credentials to a remote attacker.

Detalhes CVE

Pontuacao CVSS v3.1N/A
Publicado12/15/2017
Ultima modificacao4/20/2025
Fontenvd
Avistamentos honeypot0

Produtos afetados

changehealthcare:conserus_image_repository

Fraquezas (CWE)

CWE-611

Correlacoes IOC

Sem correlacoes registradas