TROYANOSYVIRUS
Voltar para CVEs

CVE-2017-12235

HIGHCISA KEV
7.5

Descricao

A vulnerability in the implementation of the PROFINET Discovery and Configuration Protocol (PN-DCP) for Cisco IOS 12.2 through 15.6 could allow an unauthenticated, remote attacker to cause an affected device to reload, resulting in a denial of service (DoS) condition. The vulnerability is due to the improper parsing of ingress PN-DCP Identify Request packets destined to an affected device. An attacker could exploit this vulnerability by sending a crafted PN-DCP Identify Request packet to an affected device and then continuing to send normal PN-DCP Identify Request packets to the device. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a DoS condition. This vulnerability affects Cisco devices that are configured to process PROFINET messages. Beginning with Cisco IOS Software Release 12.2(52)SE, PROFINET is enabled by default on all the base switch module and expansion-unit Ethernet ports. Cisco Bug IDs: CSCuz47179.

Detalhes CVE

Pontuacao CVSS v3.17.5
SeveridadeHIGH
Vetor CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Vetor de ataqueNETWORK
ComplexidadeLOW
Privilegios necessariosNONE
Interacao do usuarioNONE
Publicado9/29/2017
Ultima modificacao4/21/2026
Fontekev
Avistamentos honeypot0

CISA KEV

FornecedorCisco
ProdutoIOS software
Nome da vulnerabilidadeCisco IOS Software for Cisco Industrial Ethernet Switches PROFINET Denial-of-Service Vulnerability
Data inclusao KEV2022-03-03
Prazo de remediacao2022-03-24
Uso em ransomwareUnknown

Produtos afetados

cisco:industrial_ethernet_2000_16ptc-g-e_switchcisco:industrial_ethernet_2000_16ptc-g-l_switchcisco:industrial_ethernet_2000_16ptc-g-nx_switchcisco:industrial_ethernet_2000_16t67-b_switchcisco:industrial_ethernet_2000_16t67p-g-e_switchcisco:industrial_ethernet_2000_16tc-g-e_switchcisco:industrial_ethernet_2000_16tc-g-l_switchcisco:industrial_ethernet_2000_16tc-g-n_switchcisco:industrial_ethernet_2000_16tc-g-x_switchcisco:industrial_ethernet_2000_16tc-l_switchcisco:industrial_ethernet_2000_24t67-b_switchcisco:industrial_ethernet_2000_4s-ts-g-b_switchcisco:industrial_ethernet_2000_4s-ts-g-l_switchcisco:industrial_ethernet_2000_4t-b_switchcisco:industrial_ethernet_2000_4t-g-b_switchcisco:industrial_ethernet_2000_4t-g-l_switchcisco:industrial_ethernet_2000_4t-l_switchcisco:industrial_ethernet_2000_4ts-b_switchcisco:industrial_ethernet_2000_4ts-g-b_switchcisco:industrial_ethernet_2000_4ts-g-l_switchcisco:industrial_ethernet_2000_4ts-l_switchcisco:industrial_ethernet_2000_8t67-b_switchcisco:industrial_ethernet_2000_8t67p-g-e_switchcisco:industrial_ethernet_2000_8tc-b_switchcisco:industrial_ethernet_2000_8tc-g-b_switchcisco:industrial_ethernet_2000_8tc-g-e_switchcisco:industrial_ethernet_2000_8tc-g-l_switchcisco:industrial_ethernet_2000_8tc-g-n_switchcisco:industrial_ethernet_2000_8tc-l_switchcisco:industrial_ethernet_2000_series_firmwarecisco:ios

Fraquezas (CWE)

CWE-20

Correlacoes IOC

Sem correlacoes registradas

This product uses data from the NVD API but is not endorsed or certified by the NVD.