← Retour aux CVEs
CVE-2026-0640
HIGH8.8
Description
A weakness has been identified in Tenda AC23 16.03.07.52. This affects the function sscanf of the file /goform/PowerSaveSet. Executing a manipulation of the argument Time can lead to buffer overflow. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks.
Details CVE
Score CVSS v3.18.8
SeveriteHIGH
Vecteur CVSSCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vecteur d'attaqueNETWORK
ComplexiteLOW
Privileges requisLOW
Interaction utilisateurNONE
Publie1/6/2026
Derniere modification1/15/2026
Sourcenvd
Observations honeypot0
Produits affectes
tenda:ac23tenda:ac23_firmware
Faiblesses (CWE)
CWE-119CWE-120CWE-120
References
https://github.com/xyh4ck/iot_poc/blob/main/Tenda%20AC23_Buffer_Overflow/Tenda%20AC23_Buffer_Overflow.md(cna@vuldb.com)
https://github.com/xyh4ck/iot_poc/blob/main/Tenda%20AC23_Buffer_Overflow/Tenda%20AC23_Buffer_Overflow.md#poc(cna@vuldb.com)
https://vuldb.com/?ctiid.339683(cna@vuldb.com)
https://vuldb.com/?id.339683(cna@vuldb.com)
https://vuldb.com/?submit.731772(cna@vuldb.com)
https://www.tenda.com.cn/(cna@vuldb.com)
Correlations IOC
Aucune correlation enregistree
This product uses data from the NVD API but is not endorsed or certified by the NVD.