← Retour aux CVEs
CVE-2025-66052
HIGH7.2
Description
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Details CVE
Score CVSS v3.17.2
SeveriteHIGH
Vecteur CVSSCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vecteur d'attaqueNETWORK
ComplexiteLOW
Privileges requisHIGH
Interaction utilisateurNONE
Publie1/9/2026
Derniere modification1/14/2026
Sourcenvd
Observations honeypot0
Produits affectes
vivotek:ip7137vivotek:ip7137_firmware
Faiblesses (CWE)
CWE-78
References
https://cert.pl/posts/2026/01/CVE-2025-66049(cvd@cert.pl)
Correlations IOC
Aucune correlation enregistree
This product uses data from the NVD API but is not endorsed or certified by the NVD.