← Retour aux CVEs
CVE-2023-7017
CRITICAL9.8
Description
Sciener locks' firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to compromise the device.
Details CVE
Score CVSS v3.19.8
SeveriteCRITICAL
Vecteur CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vecteur d'attaqueNETWORK
ComplexiteLOW
Privileges requisNONE
Interaction utilisateurNONE
Publie3/15/2024
Derniere modification11/4/2025
Sourcenvd
Observations honeypot0
References
https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/(cret@cert.org)
https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/(af854a3a-2127-422b-91ae-364da2661108)
https://www.kb.cert.org/vuls/id/949046(af854a3a-2127-422b-91ae-364da2661108)
Correlations IOC
Aucune correlation enregistree
This product uses data from the NVD API but is not endorsed or certified by the NVD.