Description

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.

Details CVE

Score CVSS v3.17.5
SeveriteHIGH
Vecteur CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Vecteur d'attaqueNETWORK
ComplexiteLOW
Privileges requisNONE
Interaction utilisateurNONE
Publie10/31/2022
Derniere modification11/21/2024
Sourcenvd
Observations honeypot0

Produits affectes

deltaww:infrasuite_device_master

Faiblesses (CWE)

CWE-306

Correlations IOC

Aucune correlation enregistree