TROYANOSYVIRUS
Retour aux CVEs

CVE-2022-26648

HIGH
8.2

Description

A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.

Details CVE

Score CVSS v3.18.2
SeveriteHIGH
Vecteur CVSSCVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:H
Vecteur d'attaqueADJACENT_NETWORK
ComplexiteLOW
Privileges requisLOW
Interaction utilisateurNONE
Publie7/12/2022
Derniere modification11/21/2024
Sourcenvd
Observations honeypot0

Produits affectes

siemens:scalance_x200-4p_irtsiemens:scalance_x200-4p_irt_firmwaresiemens:scalance_x201-3p_irtsiemens:scalance_x201-3p_irt_firmwaresiemens:scalance_x201-3p_irt_prosiemens:scalance_x201-3p_irt_pro_firmwaresiemens:scalance_x202-2irtsiemens:scalance_x202-2irt_firmwaresiemens:scalance_x202-2p_irtsiemens:scalance_x202-2p_irt_firmwaresiemens:scalance_x202-2p_irt_prosiemens:scalance_x202-2p_irt_pro_firmwaresiemens:scalance_x204-2siemens:scalance_x204-2_firmwaresiemens:scalance_x204-2fmsiemens:scalance_x204-2fm_firmwaresiemens:scalance_x204-2ldsiemens:scalance_x204-2ld_firmwaresiemens:scalance_x204-2ld_tssiemens:scalance_x204-2ld_ts_firmwaresiemens:scalance_x204-2tssiemens:scalance_x204-2ts_firmwaresiemens:scalance_x204irtsiemens:scalance_x204irt_firmwaresiemens:scalance_x204irt_prosiemens:scalance_x204irt_pro_firmwaresiemens:scalance_x206-1siemens:scalance_x206-1_firmwaresiemens:scalance_x206-1ldsiemens:scalance_x206-1ld_firmwaresiemens:scalance_x208siemens:scalance_x208_firmwaresiemens:scalance_x208_prosiemens:scalance_x208_pro_firmwaresiemens:scalance_x212-2siemens:scalance_x212-2_firmwaresiemens:scalance_x212-2ldsiemens:scalance_x212-2ld_firmwaresiemens:scalance_x216siemens:scalance_x216_firmwaresiemens:scalance_x224siemens:scalance_x224_firmwaresiemens:scalance_xf201-3p_irtsiemens:scalance_xf201-3p_irt_firmwaresiemens:scalance_xf202-2p_irtsiemens:scalance_xf202-2p_irt_firmwaresiemens:scalance_xf204siemens:scalance_xf204-2siemens:scalance_xf204-2_firmwaresiemens:scalance_xf204-2ba_irtsiemens:scalance_xf204-2ba_irt_firmwaresiemens:scalance_xf204_firmwaresiemens:scalance_xf204irtsiemens:scalance_xf204irt_firmwaresiemens:scalance_xf206-1siemens:scalance_xf206-1_firmwaresiemens:scalance_xf208siemens:scalance_xf208_firmware

Faiblesses (CWE)

CWE-120CWE-120

Correlations IOC

Aucune correlation enregistree

This product uses data from the NVD API but is not endorsed or certified by the NVD.