TROYANOSYVIRUS
Retour aux CVEs

CVE-2021-31884

CRITICAL
9.8

Description

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)

Details CVE

Score CVSS v3.19.8
SeveriteCRITICAL
Vecteur CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vecteur d'attaqueNETWORK
ComplexiteLOW
Privileges requisNONE
Interaction utilisateurNONE
Publie11/9/2021
Derniere modification11/21/2024
Sourcenvd
Observations honeypot0

Produits affectes

siemens:apogee_modular_building_controllersiemens:apogee_modular_building_controller_firmwaresiemens:apogee_modular_equiment_controllersiemens:apogee_modular_equiment_controller_firmwaresiemens:apogee_pxc_compactsiemens:apogee_pxc_compact_firmwaresiemens:apogee_pxc_modularsiemens:apogee_pxc_modular_firmwaresiemens:capital_vstarsiemens:desigo_pxc00-e.dsiemens:desigo_pxc00-e.d_firmwaresiemens:desigo_pxc00-usiemens:desigo_pxc00-u_firmwaresiemens:desigo_pxc001-e.dsiemens:desigo_pxc001-e.d_firmwaresiemens:desigo_pxc100-e.dsiemens:desigo_pxc100-e.d_firmwaresiemens:desigo_pxc12-e.dsiemens:desigo_pxc12-e.d_firmwaresiemens:desigo_pxc128-usiemens:desigo_pxc128-u_firmwaresiemens:desigo_pxc200-e.dsiemens:desigo_pxc200-e.d_firmwaresiemens:desigo_pxc22-e.dsiemens:desigo_pxc22-e.d_firmwaresiemens:desigo_pxc22.1-e.dsiemens:desigo_pxc22.1-e.d_firmwaresiemens:desigo_pxc36.1-e.dsiemens:desigo_pxc36.1-e.d_firmwaresiemens:desigo_pxc50-e.dsiemens:desigo_pxc50-e.d_firmwaresiemens:desigo_pxc64-usiemens:desigo_pxc64-u_firmwaresiemens:desigo_pxm20-esiemens:desigo_pxm20-e_firmwaresiemens:nucleus_netsiemens:nucleus_readystart_v3siemens:nucleus_source_codesiemens:talon_tc_compactsiemens:talon_tc_compact_firmwaresiemens:talon_tc_modularsiemens:talon_tc_modular_firmware

Faiblesses (CWE)

CWE-170

Correlations IOC

Aucune correlation enregistree

This product uses data from the NVD API but is not endorsed or certified by the NVD.