Description
A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
Details CVE
Score CVSS v3.19.8
SeveriteCRITICAL
Vecteur CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vecteur d'attaqueNETWORK
ComplexiteLOW
Privileges requisNONE
Interaction utilisateurNONE
Publie9/9/2020
Derniere modification11/21/2024
Sourcenvd
Observations honeypot0
Produits affectes
siemens:simatic_hmi_united_comfort_panelssiemens:simatic_hmi_united_comfort_panels_firmware
Faiblesses (CWE)
CWE-305CWE-287
References
https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf(productcert@siemens.com)