← Retour aux CVEs
CVE-2019-5138
CRITICAL9.9
Description
An exploitable command injection vulnerability exists in encrypted diagnostic script functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted diagnostic script file can cause arbitrary busybox commands to be executed, resulting in remote control over the device. An attacker can send diagnostic while authenticated as a low privilege user to trigger this vulnerability.
Details CVE
Score CVSS v3.19.9
SeveriteCRITICAL
Vecteur CVSSCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Vecteur d'attaqueNETWORK
ComplexiteLOW
Privileges requisLOW
Interaction utilisateurNONE
Publie2/25/2020
Derniere modification11/21/2024
Sourcenvd
Observations honeypot0
Produits affectes
moxa:awk-3131amoxa:awk-3131a_firmware
Faiblesses (CWE)
CWE-78CWE-78
References
https://talosintelligence.com/vulnerability_reports/TALOS-2019-0927(talos-cna@cisco.com)
https://talosintelligence.com/vulnerability_reports/TALOS-2019-0927(af854a3a-2127-422b-91ae-364da2661108)
Correlations IOC
Aucune correlation enregistree
This product uses data from the NVD API but is not endorsed or certified by the NVD.