CVE-2016-9343

CRITICAL
10.0

Description

An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 (excluding all firmware versions prior to FRN 16.00, which are not affected). By sending malformed common industrial protocol (CIP) packet, an attacker may be able to overflow a stack-based buffer and execute code on the controller or initiate a nonrecoverable fault resulting in a denial of service.

Details CVE

Score CVSS v3.110.0
SeveriteCRITICAL
Vecteur CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vecteur d'attaqueNETWORK
ComplexiteLOW
Privileges requisNONE
Interaction utilisateurNONE
Publie2/13/2017
Derniere modification4/20/2025
Sourcenvd
Observations honeypot0

Produits affectes

rockwellautomation:1768_compact_guardlogix_l4xs_controllerrockwellautomation:1768_compact_guardlogix_l4xs_controller_firmwarerockwellautomation:1768_compactlogix_l4x_controllerrockwellautomation:1768_compactlogix_l4x_controller_firmwarerockwellautomation:1769_compactlogix_5370_l1_controllerrockwellautomation:1769_compactlogix_5370_l1_controller_firmwarerockwellautomation:1769_compactlogix_5370_l2_controllerrockwellautomation:1769_compactlogix_5370_l2_controller_firmwarerockwellautomation:1769_compactlogix_5370_l3_controllerrockwellautomation:1769_compactlogix_5370_l3_controller_firmwarerockwellautomation:1769_compactlogix_l23x_controllerrockwellautomation:1769_compactlogix_l23x_controller_firmwarerockwellautomation:1769_compactlogix_l3x_controllerrockwellautomation:1769_compactlogix_l3x_controller_firmwarerockwellautomation:controllogix_5560_controllerrockwellautomation:controllogix_5560_controller_firmwarerockwellautomation:controllogix_5560_redundant_controllerrockwellautomation:controllogix_5560_redundant_controller_firmwarerockwellautomation:controllogix_5570_controllerrockwellautomation:controllogix_5570_controller_firmwarerockwellautomation:controllogix_5570_redundant_controllerrockwellautomation:controllogix_5570_redundant_controller_firmwarerockwellautomation:controllogix_l55_controllerrockwellautomation:controllogix_l55_controller_firmwarerockwellautomation:flexlogix_l34_controllerrockwellautomation:flexlogix_l34_controller_firmwarerockwellautomation:guardlogix_5570_controllerrockwellautomation:guardlogix_5570_controller_firmwarerockwellautomation:rslogix_emulate_5000rockwellautomation:rslogix_emulate_5000_firmwarerockwellautomation:softlogix_5800_controllerrockwellautomation:softlogix_5800_controller_firmware

Faiblesses (CWE)

CWE-787

References

Correlations IOC

Aucune correlation enregistree

This product uses data from the NVD API but is not endorsed or certified by the NVD.