← Zuruck zu CVEs
CVE-2024-50374
CRITICAL9.8
Beschreibung
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
CVE Details
CVSS v3.1 Bewertung9.8
SchweregradCRITICAL
CVSS VektorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
AngriffsvektorNETWORK
KomplexitatLOW
Erforderliche PrivilegienNONE
BenutzerinteraktionNONE
Veroffentlicht11/26/2024
Zuletzt geandert1/23/2026
Quellenvd
Honeypot-Sichtungen0
Betroffene Produkte
advantech:eki-6333ac-1gpoadvantech:eki-6333ac-1gpo_firmwareadvantech:eki-6333ac-2gadvantech:eki-6333ac-2g_firmwareadvantech:eki-6333ac-2gdadvantech:eki-6333ac-2gd_firmware
Schwachen (CWE)
CWE-78
Referenzen
https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50374(prodsec@nozominetworks.com)
IOC Korrelationen
Keine Korrelationen erfasst
This product uses data from the NVD API but is not endorsed or certified by the NVD.