CVE-2023-24512
HIGH8.8
Beschreibung
On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft a request allowing it to update arbitrary configurations in the switch. This situation occurs only when the Streaming Telemetry Agent (referred to as the TerminAttr agent) is enabled and gNMI access is configured on the agent. Note: This gNMI over the Streaming Telemetry Agent scenario is mostly commonly used when streaming to a 3rd party system and is not used by default when streaming to CloudVision
CVE Details
CVSS v3.1 Bewertung8.8
SchweregradHIGH
CVSS VektorCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
AngriffsvektorNETWORK
KomplexitatLOW
Erforderliche PrivilegienLOW
BenutzerinteraktionNONE
Veroffentlicht4/25/2023
Zuletzt geandert11/21/2024
Quellenvd
Honeypot-Sichtungen0
Betroffene Produkte
arista:32qdarista:48ehsarista:48lbasarista:48lbsarista:48s6qdarista:7010t-48arista:7020sr-24c2arista:7020sr-32c2arista:7020tr-48arista:7020tra-48arista:7050cx3-32sarista:7050cx3m-32sarista:7050qx-32sarista:7050qx2-32sarista:7050sx-128arista:7050sx-64arista:7050sx-72qarista:7050sx2-128arista:7050sx2-72qarista:7050sx3-48c8arista:7050sx3-48ycarista:7050sx3-48yc12arista:7050sx3-48yc8arista:7050sx3-96yc8arista:7050tx-48arista:7050tx-64arista:7050tx-72qarista:7050tx2-128arista:7050tx3-48c8arista:7060cx-32sarista:7060cx2-32sarista:7060dx4-32arista:7060px4-32arista:7060sx2-48yc6arista:7130-16g3sarista:7130-48g3sarista:7130-96sarista:7150s-24arista:7150s-52arista:7150s-64arista:7150sc-24arista:7150sc-64arista:7160-32cqarista:7160-48tc6arista:7160-48yc6arista:7170-32carista:7170-32cdarista:7170-64carista:7170b-64carista:720df-48yarista:720dp-24sarista:720dp-48sarista:720dt-24sarista:720dt-48sarista:720xp-24y6arista:720xp-24zy4arista:720xp-48y6arista:720xp-48zc2arista:720xp-96zc2arista:7250qx-64arista:7260cxarista:7260cx3arista:7260qxarista:7260sx2arista:7280cr2k-60arista:7280cr3-32d4arista:7280cr3-32p4arista:7280cr3-96arista:7280cr3k-32d4arista:7280cr3k-32p4arista:7280cr3k-96arista:7280dr3-24arista:7280dr3k-24arista:7280earista:7280pr3-24arista:7280pr3k-24arista:7280sr3-48yc8arista:7280sr3k-48yc8arista:7300x-32qarista:7300x-64sarista:7300x-64tarista:7300x3-32carista:7300x3-48yc4arista:7320x-32carista:7358x4arista:7368x4arista:7388x5arista:7500r3-24darista:7500r3-24parista:7500r3-36cqarista:7500r3k-36cqarista:7804r3arista:7808r3arista:7812r3arista:7816r3arista:96lbsarista:ceos-labarista:cloudeosarista:dcs-7010tx-48arista:dcs-7500-12cq-lcarista:dcs-7500e-12cm-lcarista:dcs-7500e-36q-lcarista:dcs-7500e-48s-lcarista:dcs-7500e-6c2-lcarista:dcs-7500e-72s-lcarista:dcs-7500r-36cq-lcarista:dcs-7500r-36q-lcarista:dcs-7500r-48s2cq-lcarista:eosarista:veos-lab
Schwachen (CWE)
CWE-284CWE-863
Referenzen
https://www.arista.com/en/support/advisories-notices/security-advisory/17250-security-advisory-0086(psirt@arista.com)
https://www.arista.com/en/support/advisories-notices/security-advisory/17250-security-advisory-0086(af854a3a-2127-422b-91ae-364da2661108)