Beschreibung

Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227.

CVE Details

CVSS v3.1 Bewertung8.8
SchweregradHIGH
CVSS VektorCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
AngriffsvektorNETWORK
KomplexitatLOW
Erforderliche PrivilegienLOW
BenutzerinteraktionNONE
Veroffentlicht5/7/2024
Zuletzt geandert8/14/2025
Quellenvd
Honeypot-Sichtungen0

Betroffene Produkte

trianglemicroworks:scada_data_gateway

Schwachen (CWE)

CWE-22

Referenzen

IOC Korrelationen

Keine Korrelationen erfasst