← Zuruck zu CVEs
CVE-2020-25229
HIGH7.5
Beschreibung
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any affected device if using prepared messages that were generated for another device.
CVE Details
CVSS v3.1 Bewertung7.5
SchweregradHIGH
CVSS VektorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
AngriffsvektorNETWORK
KomplexitatLOW
Erforderliche PrivilegienNONE
BenutzerinteraktionNONE
Veroffentlicht12/14/2020
Zuletzt geandert11/21/2024
Quellenvd
Honeypot-Sichtungen0
Betroffene Produkte
siemens:logo\!_8_bmsiemens:logo\!_8_bm_firmware
Schwachen (CWE)
CWE-321CWE-798
Referenzen
https://cert-portal.siemens.com/productcert/pdf/ssa-480824.pdf(productcert@siemens.com)
https://cert-portal.siemens.com/productcert/pdf/ssa-480824.pdf(af854a3a-2127-422b-91ae-364da2661108)
IOC Korrelationen
Keine Korrelationen erfasst
This product uses data from the NVD API but is not endorsed or certified by the NVD.