TROYANOSYVIRUS
Zuruck zu CVEs

CVE-2019-6538

CRITICAL
9.3

Beschreibung

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.

CVE Details

CVSS v3.1 Bewertung9.3
SchweregradCRITICAL
CVSS VektorCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H
AngriffsvektorADJACENT_NETWORK
KomplexitatLOW
Erforderliche PrivilegienNONE
BenutzerinteraktionNONE
Veroffentlicht3/25/2019
Zuletzt geandert5/22/2025
Quellenvd
Honeypot-Sichtungen0

Betroffene Produkte

medtronic:amplia_crt-dmedtronic:amplia_crt-d_firmwaremedtronic:carelink_2090medtronic:carelink_2090_firmwaremedtronic:carelink_monitormedtronic:carelink_monitor_firmwaremedtronic:claria_crt-dmedtronic:claria_crt-d_firmwaremedtronic:compia_crt-dmedtronic:compia_crt-d_firmwaremedtronic:concerto_crt-dmedtronic:concerto_crt-d_firmwaremedtronic:concerto_ii_crt-dmedtronic:concerto_ii_crt-d_firmwaremedtronic:consulta_crt-dmedtronic:consulta_crt-d_firmwaremedtronic:evera_icdmedtronic:evera_icd_firmwaremedtronic:maximo_ii_crt-d_and_lcdmedtronic:maximo_ii_crt-d_and_lcd_firmwaremedtronic:mirro_icdmedtronic:mirro_icd_firmwaremedtronic:mycarelink_monitormedtronic:mycarelink_monitor_firmwaremedtronic:nayamed_nd_icdmedtronic:nayamed_nd_icd_firmwaremedtronic:primo_icdmedtronic:primo_icd_firmwaremedtronic:protecta_icd_and_crt-dmedtronic:protecta_icd_and_crt-d_firmwaremedtronic:secura_icdmedtronic:secura_icd_firmwaremedtronic:virtuoso_icdmedtronic:virtuoso_icd_firmwaremedtronic:virtuoso_ii_icdmedtronic:virtuoso_ii_icd_firmwaremedtronic:visia_af_icdmedtronic:visia_af_icd_firmwaremedtronic:viva_crt-dmedtronic:viva_crt-d_firmware

Schwachen (CWE)

CWE-284CWE-306CWE-862

Referenzen

IOC Korrelationen

Keine Korrelationen erfasst

This product uses data from the NVD API but is not endorsed or certified by the NVD.