← Zuruck zu CVEs
CVE-2019-18337
CRITICAL9.8
Beschreibung
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote attacker with network access to the CCS server could exploit this vulnerability to read the CCS users database, including the passwords of all users in obfuscated cleartext.
CVE Details
CVSS v3.1 Bewertung9.8
SchweregradCRITICAL
CVSS VektorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
AngriffsvektorNETWORK
KomplexitatLOW
Erforderliche PrivilegienNONE
BenutzerinteraktionNONE
Veroffentlicht12/12/2019
Zuletzt geandert11/21/2024
Quellenvd
Honeypot-Sichtungen0
Betroffene Produkte
siemens:sinvr_3_central_control_serversiemens:sinvr_3_video_server
Schwachen (CWE)
CWE-287CWE-287
Referenzen
https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf(productcert@siemens.com)
https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf(productcert@siemens.com)
https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf(af854a3a-2127-422b-91ae-364da2661108)
https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf(af854a3a-2127-422b-91ae-364da2661108)
IOC Korrelationen
Keine Korrelationen erfasst
This product uses data from the NVD API but is not endorsed or certified by the NVD.