← Zuruck zu CVEs
CVE-2018-11422
N/ABeschreibung
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including device reboot, configuration download or upload, or firmware upgrade) are accepted and executed by the device without authentication.
CVE Details
CVSS v3.1 BewertungN/A
Veroffentlicht7/3/2019
Zuletzt geandert11/21/2024
Quellenvd
Honeypot-Sichtungen0
Betroffene Produkte
moxa:oncell_g3150-hspamoxa:oncell_g3150-hspa-tmoxa:oncell_g3150-hspa-t_firmwaremoxa:oncell_g3150-hspa_firmware
Schwachen (CWE)
CWE-319
Referenzen
https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-104.md(af854a3a-2127-422b-91ae-364da2661108)
IOC Korrelationen
Keine Korrelationen erfasst
This product uses data from the NVD API but is not endorsed or certified by the NVD.