TROYANOSYVIRUS
Volver a CVEs

CVE-2026-21897

HIGH
7.3

Descripcion

CryptoLib provides a software-only solution using the CCSDS Space Data Link Security Protocol - Extended Procedures (SDLS-EP) to secure communications between a spacecraft running the core Flight System (cFS) and a ground station. Prior to version 1.4.3, the Crypto_Config_Add_Gvcid_Managed_Parameters function only checks whether gvcid_counter > GVCID_MAN_PARAM_SIZE. As a result, it allows up to the 251st entry, which causes a write past the end of the array, overwriting gvcid_counter located immediately after gvcid_managed_parameters_array[250]. This leads to an out-of-bounds write, and the overwritten gvcid_counter may become an arbitrary value, potentially affecting the parameter lookup/registration logic that relies on it. This issue has been patched in version 1.4.3.

Detalles CVE

Puntuacion CVSS v3.17.3
SeveridadHIGH
Vector CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Vector de ataqueNETWORK
ComplejidadLOW
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado1/10/2026
Ultima modificacion1/15/2026
Fuentenvd
Avistamientos honeypot0

Productos afectados

nasa:cryptolib

Debilidades (CWE)

CWE-787

Correlaciones IOC

Sin correlaciones registradas