← Volver a CVEs
CVE-2025-5442
MEDIUM6.3
Descripcion
A vulnerability, which was classified as critical, has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function RP_pingGatewayByBBS of the file /goform/RP_pingGatewayByBBS. The manipulation of the argument ip/nm/gw leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Detalles CVE
Puntuacion CVSS v3.16.3
SeveridadMEDIUM
Vector CVSSCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Vector de ataqueNETWORK
ComplejidadLOW
Privilegios requeridosLOW
Interaccion usuarioNONE
Publicado6/2/2025
Ultima modificacion6/25/2025
Fuentenvd
Avistamientos honeypot0
Productos afectados
linksys:re6250linksys:re6250_firmwarelinksys:re6300linksys:re6300_firmwarelinksys:re6350linksys:re6350_firmwarelinksys:re6500linksys:re6500_firmwarelinksys:re7000linksys:re7000_firmwarelinksys:re9000linksys:re9000_firmware
Debilidades (CWE)
CWE-77CWE-78CWE-78
Referencias
https://vuldb.com/?ctiid.310781(cna@vuldb.com)
https://vuldb.com/?id.310781(cna@vuldb.com)
https://vuldb.com/?submit.584364(cna@vuldb.com)
https://www.linksys.com/(cna@vuldb.com)
https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_5/5.md(134c704f-9b21-4f2e-91b3-4a467353bcc0)
Correlaciones IOC
Sin correlaciones registradas