← Volver a CVEs
CVE-2025-25675
CRITICAL9.8
Descripcion
Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmd_buf variable, which is directly used in the doSystemCmd function, causing an arbitrary command execution.
Detalles CVE
Puntuacion CVSS v3.19.8
SeveridadCRITICAL
Vector CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vector de ataqueNETWORK
ComplejidadLOW
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado2/20/2025
Ultima modificacion3/17/2025
Fuentenvd
Avistamientos honeypot0
Productos afectados
tenda:ac10tenda:ac10_firmware
Debilidades (CWE)
CWE-77CWE-94
Referencias
Correlaciones IOC
Sin correlaciones registradas
This product uses data from the NVD API but is not endorsed or certified by the NVD.