CRITICAL9.8
Descripcion
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.
Detalles CVE
Puntuacion CVSS v3.19.8
SeveridadCRITICAL
Vector CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vector de ataqueNETWORK
ComplejidadLOW
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado11/26/2024
Ultima modificacion1/23/2026
Fuentenvd
Avistamientos honeypot0
Productos afectados
advantech:eki-6333ac-1gpoadvantech:eki-6333ac-1gpo_firmwareadvantech:eki-6333ac-2gadvantech:eki-6333ac-2g_firmwareadvantech:eki-6333ac-2gdadvantech:eki-6333ac-2gd_firmware