← Volver a CVEs
CVE-2024-31146
HIGH7.5
Descripcion
When multiple devices share resources and one of them is to be passed through to a guest, security of the entire system and of respective guests individually cannot really be guaranteed without knowing internals of any of the involved guests. Therefore such a configuration cannot really be security-supported, yet making that explicit was so far missing. Resources the sharing of which is known to be problematic include, but are not limited to - - PCI Base Address Registers (BARs) of multiple devices mapping to the same page (4k on x86), - - INTx lines.
Detalles CVE
Puntuacion CVSS v3.17.5
SeveridadHIGH
Vector CVSSCVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H
Vector de ataqueLOCAL
ComplejidadHIGH
Privilegios requeridosHIGH
Interaccion usuarioNONE
Publicado9/25/2024
Ultima modificacion1/5/2026
Fuentenvd
Avistamientos honeypot0
Productos afectados
xen:xen
Debilidades (CWE)
CWE-400
Referencias
https://xenbits.xenproject.org/xsa/advisory-461.html(security@xen.org)
http://www.openwall.com/lists/oss-security/2024/08/14/3(af854a3a-2127-422b-91ae-364da2661108)
http://xenbits.xen.org/xsa/advisory-461.html(af854a3a-2127-422b-91ae-364da2661108)
Correlaciones IOC
Sin correlaciones registradas
This product uses data from the NVD API but is not endorsed or certified by the NVD.