← Volver a CVEs
CVE-2023-34257
CRITICAL9.8
Descripcion
An issue was discovered in BMC Patrol through 23.1.00. The agent's configuration can be remotely modified (and, by default, authentication is not required). Some configuration fields related to SNMP (e.g., masterAgentName or masterAgentStartLine) result in code execution when the agent is restarted. NOTE: the vendor's perspective is "These are not vulnerabilities for us as we have provided the option to implement the authentication."
Detalles CVE
Puntuacion CVSS v3.19.8
SeveridadCRITICAL
Vector CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vector de ataqueNETWORK
ComplejidadLOW
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado5/31/2023
Ultima modificacion1/10/2025
Fuentenvd
Avistamientos honeypot0
Productos afectados
bmc:patrol_agent
Referencias
https://www.errno.fr/PatrolAdvisory.html#remote-code-excution-using-patrols-pconfig(af854a3a-2127-422b-91ae-364da2661108)
Correlaciones IOC
Sin correlaciones registradas
This product uses data from the NVD API but is not endorsed or certified by the NVD.