TROYANOSYVIRUS
Volver a CVEs

CVE-2023-29468

CRITICAL
9.8

Descripcion

The Texas Instruments (TI) WiLink WL18xx MCP driver does not limit the number of information elements (IEs) of type XCC_EXT_1_IE_ID or XCC_EXT_2_IE_ID that can be parsed in a management frame. Using a specially crafted frame, a buffer overflow can be triggered that can potentially lead to remote code execution. This affects WILINK8-WIFI-MCP8 version 8.5_SP3 and earlier.

Detalles CVE

Puntuacion CVSS v3.19.8
SeveridadCRITICAL
Vector CVSSCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vector de ataqueNETWORK
ComplejidadLOW
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado8/14/2023
Ultima modificacion5/5/2025
Fuentenvd
Avistamientos honeypot0

Productos afectados

ti:wilink8-wifi-mcp8

Debilidades (CWE)

CWE-120CWE-120

Referencias

https://www.ti.com/lit/swra773(af854a3a-2127-422b-91ae-364da2661108)

Correlaciones IOC

Sin correlaciones registradas